| Product type |
Window motor |
| Product name |
1040-INT Mk 2 |
| Manufacturer |
Intacall Ltd
Archer House
Britland Estate
Northbourne Road
Eastbourne
East Sussex
BN22 8PW
Tel. 01323 430278
Fax. 01323 416211
|
|
| Power supply |
240V mains
transformed to 24V using internal transformer
|
| Back-up power |
N/A
|
| Description |
Window motor for
side- and top-hung windows.
|
| Features |
•
Safety stop. If
load sensors detect an obstruction, the motor will cut out.
• Emergency window release.
|
| Testing method |
7,000 continuous
operations using link power.
Safety stop tested using the barrel of a biro. Not successful.
During a forced entry attack, the emergency window release released.
|
| Comments |
• The standard
installation method would use an in-built transformer. This was replaced
by a direct feed from the low voltage network.
• An external interface card was also fitted that provided the safety
stop feature.
• The motor itself resisted a forced opening attack from outside, though
the mounting bracket proved vulnerable to force applied from the side.
• The emergency release proved awkward to operate. This could be fitted
with a longer pin with a handle so it may be removed more easily in an
emergency.
• Currently the motor is networked by an externally mounted interface.
An integrated network card, which supplied the motor with low voltage
power, would make it easier to install and provide additional network
functionality (particularly load monitoring for safety purposes). |
| |
<< Back |